Lead-out and termination end

Electromagnetic Compatibility Design High-precision Display Multi-point Positioning Detection Built-in Memory Dual Relay Output Automatic Address Sorting

Product Inquiries:

  • Product Description
    • Commodity name: Lead-out and termination end

    Electromagnetic Compatibility Design High-precision Display Multi-point Positioning Detection Built-in Memory Dual Relay Output Automatic Address Sorting

    Functional Features

    Electromagnetic Compatibility Design

    The device features electromagnetic compatibility design, with EMC Level 4 protection, strong anti-interference capability, and high reliability.

    High Mathematics Display

    7-inch HD touchscreen for viewing leak data and setting system parameters such as IP address, baud rate, and clock.

    Multi-point positioning detection

    Multi-point positioning detection over long distances can be achieved using node-based positioning induction lines.

    Built-in memory

    128 historical data records can be saved, allowing for the logging of alarm information and leakage data, facilitating information traceability.

    Dual relay output

    Equipped with relay outputs for leak and fault alarms, it can interlock with peripheral devices and quickly distinguish between alarm types.

    Automatic address sorting

    The nodal positioning induction wire features automatic sorting functionality, eliminating the need for manual parameter settings. It’s simple and convenient to install.

     

    Technical Parameters

    Project   Project  
    Supply voltage DC 24V +5% (isolated power supply) Induction wire specifications 5m/10m/15m/20m/25m/30m
    Operating temperature -20℃~70℃ (controller), -40℃~70℃ (node) Flame-retardant rating UL94-V0 (node)
    Working humidity 0–95% RH (no condensation) Protection rating IP65 (node)
    Detection distance ≤1500m (with ≤64 connection nodes) Communication method RS485, TCP/IP
    Response time ≤5s (node) Alarm Type 2-group relay output
    Detection accuracy ±0.3 m + 1% FS Output type Leak/Failure Alarm
    Installation method  
Keywords: Lead-out and termination end